<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">rmt</journal-id><journal-title-group><journal-title xml:lang="ru">Общая реаниматология</journal-title><trans-title-group xml:lang="en"><trans-title>General Reanimatology</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1813-9779</issn><issn pub-type="epub">2411-7110</issn><publisher><publisher-name>FSBI "SRIGR" RAMS</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.15360/1813-9779-2021-4-37-47</article-id><article-id custom-type="elpub" pub-id-type="custom">rmt-2101</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ПРАКТИКУЮЩЕМУ ВРАЧУ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>FOR PRACTIONER</subject></subj-group></article-categories><title-group><article-title>Оценка качества компрессий грудной клетки, проводимых медицинскими работниками в симулированных условиях</article-title><trans-title-group xml:lang="en"><trans-title>Assessment of the Quality of Chest Compressions Performed by Health-Care Workers Under Simulated Conditions</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Боева</surname><given-names>Е. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Boeva</surname><given-names>E. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Екатерина Александровна Боева</p><p>107031, г. Москва, ул. Петровка, д. 25, стр. 2</p></bio><bio xml:lang="en"><p>Ekaterina A. Boeva</p><p>25 Petrovka Str., Bldg. 2, 107031 Moscow</p></bio><email xlink:type="simple">eboeva@fnkcrr.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Старостин</surname><given-names>Д. О.</given-names></name><name name-style="western" xml:lang="en"><surname>Starostin</surname><given-names>D. O.</given-names></name></name-alternatives><bio xml:lang="ru"><p>107031, г. Москва, ул. Петровка, д. 25, стр. 2</p></bio><bio xml:lang="en"><p>Daniil O. Starostin</p><p>25 Petrovka Str., Bldg. 2, 107031 Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Милованова</surname><given-names>М. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Milovanova</surname><given-names>M. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>107031, г. Москва, ул. Петровка, д. 25, стр. 2</p></bio><bio xml:lang="en"><p>Marina A. Milovanova</p><p>25 Petrovka Str., Bldg. 2, 107031 Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Антонова</surname><given-names>В. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Antonova</surname><given-names>V. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>107031, г. Москва, ул. Петровка, д. 25, стр. 2</p></bio><bio xml:lang="en"><p>Victoria V. Antonova</p><p>25 Petrovka Str., Bldg. 2, 107031 Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Каргин</surname><given-names>Д. Ч.</given-names></name><name name-style="western" xml:lang="en"><surname>Kargin</surname><given-names>D. Ch.</given-names></name></name-alternatives><bio xml:lang="ru"><p>107031, г. Москва, ул. Петровка, д. 25, стр. 2</p></bio><bio xml:lang="en"><p>Diego Ch. Kargin</p><p>25 Petrovka Str., Bldg. 2, 107031 Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Абдусаламов</surname><given-names>С. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Abdusalamov</surname><given-names>S. N.</given-names></name></name-alternatives><bio xml:lang="ru"><p>115682, г. Москва, Ореховый бульвар, д. 28</p></bio><bio xml:lang="en"><p>Sergei N. Abdusalamov</p><p>28 Orekhovyy bul'var, 115682 Moscow</p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>НИИ общей реаниматологии им. В. А. Неговского ФНКЦ РР</institution><country>Россия</country></aff><aff xml:lang="en"><institution>V. A. Negovsky Research Institute of General Reanimatology, Federal Research and Clinical Center of Intensive Care Medicine and Rehabilitology</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФНКЦ специализированных видов медицинской помощи и медицинских технологий Федерального медико-биологического агентства России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Federal Research and Clinical Center for Specialized Types of Medical Care and Medical Technology, Federal Medical-Biological Agency of Russia</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2021</year></pub-date><pub-date pub-type="epub"><day>27</day><month>08</month><year>2021</year></pub-date><volume>17</volume><issue>4</issue><fpage>37</fpage><lpage>47</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Боева Е.А., Старостин Д.О., Милованова М.А., Антонова В.В., Каргин Д.Ч., Абдусаламов С.Н., 2021</copyright-statement><copyright-year>2021</copyright-year><copyright-holder xml:lang="ru">Боева Е.А., Старостин Д.О., Милованова М.А., Антонова В.В., Каргин Д.Ч., Абдусаламов С.Н.</copyright-holder><copyright-holder xml:lang="en">Boeva E.A., Starostin D.O., Milovanova M.A., Antonova V.V., Kargin D.C., Abdusalamov S.N.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.reanimatology.com/rmt/article/view/2101">https://www.reanimatology.com/rmt/article/view/2101</self-uri><abstract><sec><title>Цель исследования</title><p>Цель исследования: изучить параметры компрессий грудной клетки медицинскими работниками городских стационаров в симулированных условиях без применения и с применением датчика контроля качества компрессий.</p></sec><sec><title>Материалы и методы</title><p>Материалы и методы. Исследование провели в многопрофильных стационарах г. Москвы. В исследование включили 359 медицинских сотрудника. Сотрудников разделили на 4 группы: врачи (n=97) и медицинские сестры (n=82) отделений реанимации (ОРИТ), врачи (n=92) и медицинские сестры (n=88) профильных отделений. Участники выполняли 2 минуты компрессий грудной клетки без применения датчика контроля качества компрессий грудной клетки (КГК), затем 2 минуты компрессий грудной клетки с применением датчика от дефибриллятора при включенных аудиовизуальных подсказках прибора. Анализировали процент целевых компрессий, частоту и глубину компрессий.</p></sec><sec><title>Результаты</title><p>Результаты. Параметры компрессий в группе врачей ОРИТ выходили за пределы референсных значений (% целевых компрессий — 0,5 (0,0; 14,5)%, частота 124,1±17,8 в минуту, глубина 5,6±1,1 см), в группе медицинских сестер ОРИТ — % целевых компрессий — 0,0 (0,0; 3,5) %, частота 123,6±23,7 в минуту, глубина 5,3±1,2 см, в группе врачей профильных отделений — % целевых компрессий — 0,0 (0,0; 1,2)%, частота 123,8±23,2 в минуту, глубина 5,8±1,2 см, в группе медицинских сестер профильных отделений — % целевых компрессий 0,0 (0,0; 6,1)%, частота 119,7±29,5 в минуту, глубина 5,6±1,2 см. При применении датчика параметры компрессий статистически значимо улучшились во всех группах: врачи ОРИТ — % целевых компрессий 81,6 (64,80; 87,90)%, частота 124,1±17,8 в минуту, глубина 5,5±0,2 см; медицинские сестры ОРИТ — % целевых компрессий 69,1 (47,4; 80,6), частота 123,6±23,7 в минуту, глубина 5,3±0,3 см, врачи профильных отделений — % целевых компрессий 69,30 (50,50; 78,70), частота 123,8±23,2 в минуту, глубина 5,4±0,3 см, медицинские сестры профильных отделений — % целевых компрессий 63,70 (42,90; 75,80), частота 119,7±29,5 в минуту, глубина 5,4±0,3 см. Отличий анализируемых параметров компрессий между сотрудниками различных отделений и должностей не выявили.</p></sec><sec><title>Заключение</title><p>Заключение. Параметры компрессий (% целевых компрессий, частота, глубина) не зависели от отделения, в котором работает сотрудник, и занимаемой должности (врач, медицинская сестра). Применение датчика контроля качества компрессий позволило улучшить параметры компрессий за счет снижения их частоты и нормализации глубины. Применение датчика не позволяет увеличить % целевых компрессий до максимальных значений, что свидетельствует о необходимости проведения обучения преподавателем.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Aim of the study</title><p>Aim of the study: to investigate chest compression parameters by city hospital staﬀ under simulated conditions with and without the use of a sensor device for quality control of chest compressions.</p></sec><sec><title>Materials and Methods</title><p>Materials and Methods. The study was conducted in Moscow's multidisciplinary hospitals. The study included 359 medical staﬀ members. The participants were divided into 4 groups: physicians (n=97) and nurses (n=82) from intensive care units (ICU) and physicians (n=92) and nurses (n=88) from specialized departments. Participants performed 2 minutes of chest compressions without a chest compressions quality control (CCQC) sensor, followed by 2 minutes of chest compressions using a deﬁbrillator sensor with audiovisual prompts from the device turned on. The percentage of target compressions, rate and depth of compressions were analyzed.</p></sec><sec><title>Results</title><p>Results. Compression parameters in the group of ICU doctors were outside the reference range (% target compression — 0.5 (0.0; 14.5)%, rate 124.1±17.8 per minute, depth 5.6±1.1 cm), in the group of ICU nurses, the percentage of target compressions was 0.0 (0.0; 3.5)%, rate — 123.6±23.7 per minute, depth — 5.3±1.2 cm, in the group of specialist doctors the percentage of target compressions was 0.0 (0.0; 1.2) %, rate — 123.8±23.2 per minute, depth — 5.8±1.2 cm, in specialized nurses group the percentage of target compressions was 0.0 (0.0; 6.1)%, rate — 119.7±29.5 per minute, depth — 5.6±1.2 cm. There was a signiﬁcant improvement in compression performance in all groups when the sensor device was used: in ICU physicians the percentage of target compressions was 81.6 (64.80; 87.90)%, rate — 124.1±17.8 per minute, depth — 5.5±0.2 cm; in ICU nurses the percentage of target compressions was 69.1 (47.4; 80.6), rate — 123.6±23.7 per minute, depth — 5.3±0.3 cm, in specialist doctors the percentage of target compressions was 69.30 (50.50; 78.70), rate — 123.8±23.2 per minute, depth — 5.4±0.3 cm, in specialized nurses the percentage of target compressions reached 63.70 (42.90; 75.80), rate — 119.7±29.5 per minute, depth — 5.4±0.3 cm. There were no diﬀerences in analysed compression parameters between staﬀ in diﬀerent departments or positions.</p></sec><sec><title>Conclusion</title><p>Conclusion. Compression parameters (percentage of target compressions, rate, depth) were not inﬂuenced by the department where the staﬀ member worked and the position held (doctor or nurse). The use of a compression quality sensor device has improved compression parameters by reducing rate and normalizing depth. The use of the sensor does not increase the percentage of target compressions to the maximum values, indicating the need for training by an instructor.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>компрессии грудной клетки</kwd><kwd>частота компрессий</kwd><kwd>глубина компрессий</kwd></kwd-group><kwd-group xml:lang="en"><kwd>chest compressions</kwd><kwd>rate of compressions</kwd><kwd>depth of compressions</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Andersen L.W., Holmberg M.J., Berg K.M., Donnino M.W., Granfeldt A. In-Hospital Cardiac Arrest: A Review. JAMA. 2019; 321 (12): 1200–1210. DOI: 10.1001/jama.2019.1696</mixed-citation><mixed-citation xml:lang="en">Andersen L.W., Holmberg M.J., Berg K.M., Donnino M.W., Granfeldt A. In-Hospital Cardiac Arrest: A Review. JAMA. 2019; 321 (12): 1200–1210. DOI: 10.1001/jama.2019.1696</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Nassar B.S., Kerber R. Improving CPR Performance. Chest. 2017; 152 (5): 1061-1069. DOI: 10.1016/j.chest.2017.04.178</mixed-citation><mixed-citation xml:lang="en">Nassar B.S., Kerber R. Improving CPR Performance. Chest. 2017; 152 (5): 1061-1069. DOI: 10.1016/j.chest.2017.04.178</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Rohlin O., Taeri T., Netzereab S., Ullemark E., Djärv T. Duration of CPR and impact on 30-day survival after ROSC for in-hospital cardiac arrest-A Swedish cohort study. Resuscitation. 2018; 132: 1–5. DOI: 10.1016/j.resuscitation.2018.08.017</mixed-citation><mixed-citation xml:lang="en">Rohlin O., Taeri T., Netzereab S., Ullemark E., Djärv T. Duration of CPR and impact on 30-day survival after ROSC for in-hospital cardiac arrest-A Swedish cohort study. Resuscitation. 2018; 132: 1–5. DOI: 10.1016/j.resuscitation.2018.08.017</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Pessach I.M., Paret G. Pediatric In-Hospital Cardiac Arrest-Can We Do Better? Pediatr Crit Care Med. 2019; 20 (3): 293–294. DOI: 10.1097/PCC.0000000000001856</mixed-citation><mixed-citation xml:lang="en">Pessach I.M., Paret G. Pediatric In-Hospital Cardiac Arrest-Can We Do Better? Pediatr Crit Care Med. 2019; 20 (3): 293–294. DOI: 10.1097/PCC.0000000000001856</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Panchal A.R., Berg K.M., Hirsch K.G., Kudenchuk P.J., Del Rios M., Cabañas J.G., Link M.S., Kurz M.C., Chan P.S., Morley P.T., Hazinski M.F., Donnino M.W. 2019 American Heart Association Focused Update on Advanced Cardiovascular Life Support: Use of Advanced Airways, Vasopressors, and Extracorporeal Cardiopulmonary Resuscitation During Cardiac Arrest: An Update to the American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2019; 140 (24): 881–894. DOI: 10.1161/CIR.0000000000000732</mixed-citation><mixed-citation xml:lang="en">Panchal A.R., Berg K.M., Hirsch K.G., Kudenchuk P.J., Del Rios M., Cabañas J.G., Link M.S., Kurz M.C., Chan P.S., Morley P.T., Hazinski M.F., Donnino M.W. 2019 American Heart Association Focused Update on Advanced Cardiovascular Life Support: Use of Advanced Airways, Vasopressors, and Extracorporeal Cardiopulmonary Resuscitation During Cardiac Arrest: An Update to the American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2019; 140 (24): 881–894. DOI: 10.1161/CIR.0000000000000732</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Myat A., Song K.J., Rea T. Out-of-hospital cardiac arrest: current concepts. Lancet. 2018; 391 (10124): 970–979. DOI: 10.1016/S0140-6736(18)30472-0</mixed-citation><mixed-citation xml:lang="en">Myat A., Song K.J., Rea T. Out-of-hospital cardiac arrest: current concepts. Lancet. 2018; 391 (10124): 970–979. DOI: 10.1016/S0140-6736(18)30472-0</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Duval S, Pepe P.E., Aufderheide T.P., Goodloe J.M., Debaty G., Labarère J., Sugiyama A., Yannopoulos D. Optimal Combination of Compression Rate and Depth During Cardiopulmonary Resuscitation for Functionally Favorable Survival. JAMA Cardiol. 2019; 4 (9): 900–908. DOI: 10.1001/jamacardio.2019.2717</mixed-citation><mixed-citation xml:lang="en">Duval S, Pepe P.E., Aufderheide T.P., Goodloe J.M., Debaty G., Labarère J., Sugiyama A., Yannopoulos D. Optimal Combination of Compression Rate and Depth During Cardiopulmonary Resuscitation for Functionally Favorable Survival. JAMA Cardiol. 2019; 4 (9): 900–908. DOI: 10.1001/jamacardio.2019.2717</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Yannopoulos D., McKnite S., Aufderheide T.P., Sigurdsson G., Pirrallo R.G., Benditt D., Lurie K.G. Eﬀects of incomplete chest wall decompression during cardiopulmonary resuscitation on coronary and cerebral perfusion pressures in a porcine model of cardiac arrest. Resuscitation. 2005; 64 (3): 363–372. DOI: 10.1016/j.resuscitation.2004.10.009</mixed-citation><mixed-citation xml:lang="en">Yannopoulos D., McKnite S., Aufderheide T.P., Sigurdsson G., Pirrallo R.G., Benditt D., Lurie K.G. Eﬀects of incomplete chest wall decompression during cardiopulmonary resuscitation on coronary and cerebral perfusion pressures in a porcine model of cardiac arrest. Resuscitation. 2005; 64 (3): 363–372. DOI: 10.1016/j.resuscitation.2004.10.009</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Oermann M.H., Krusmark M.A., Kardong-Edgren S., Jastrzembski T.S., Gluck K.A. Training interval in cardiopulmonary resuscitation. PLoS One. 2020; 15 (1): e0226786. DOI: 10.1371/journal.pone.0226786</mixed-citation><mixed-citation xml:lang="en">Oermann M.H., Krusmark M.A., Kardong-Edgren S., Jastrzembski T.S., Gluck K.A. Training interval in cardiopulmonary resuscitation. PLoS One. 2020; 15 (1): e0226786. DOI: 10.1371/journal.pone.0226786</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Riggs M., Franklin R., Saylany L. Associations between cardiopulmonary resuscitation (CPR) knowledge, self-eﬃcacy, training history and willingness to perform CPR and CPR psychomotor skills: A systematic review. Resuscitation. 2019; 138: 259–272. DOI: 10.1016/j.resuscitation.2019.03.019</mixed-citation><mixed-citation xml:lang="en">Riggs M., Franklin R., Saylany L. Associations between cardiopulmonary resuscitation (CPR) knowledge, self-eﬃcacy, training history and willingness to perform CPR and CPR psychomotor skills: A systematic review. Resuscitation. 2019; 138: 259–272. DOI: 10.1016/j.resuscitation.2019.03.019</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Brown L.L., Lin Y., Toﬁl N.M., Overly F., Duﬀ J.P., Bhanji F., Nadkarni V.M., Hunt E.A., Bragg A., Kessler D., Bank I., Cheng A. International Network for Simulation-based Pediatric Innovation, Research, Education CPR Investigators (INSPIRE). Impact of a CPR feedback device on healthcare provider workload during simulated cardiac arrest. Resuscitation. 2018; 130: 111–117. DOI: 10.1016/j.resuscitation.2018.06.035</mixed-citation><mixed-citation xml:lang="en">Brown L.L., Lin Y., Toﬁl N.M., Overly F., Duﬀ J.P., Bhanji F., Nadkarni V.M., Hunt E.A., Bragg A., Kessler D., Bank I., Cheng A. International Network for Simulation-based Pediatric Innovation, Research, Education CPR Investigators (INSPIRE). Impact of a CPR feedback device on healthcare provider workload during simulated cardiac arrest. Resuscitation. 2018; 130: 111–117. DOI: 10.1016/j.resuscitation.2018.06.035</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Monsieurs K.G., Nolan J.P., Bossaert L.L., Greif R., Maconochie I.K., Nikolaou N.I., Perkins G.D., Soar J., Truhlář A., Wyllie J., Zideman D.A. ERC Guidelines 2015 Writing Group. European Resuscitation Council Guidelines for Resuscitation 2015: Section 1. Executive summary. Resuscitation. 2015; 95: 1-80. DOI: 10.1016/j.resuscitation.2015.07.038</mixed-citation><mixed-citation xml:lang="en">Monsieurs K.G., Nolan J.P., Bossaert L.L., Greif R., Maconochie I.K., Nikolaou N.I., Perkins G.D., Soar J., Truhlář A., Wyllie J., Zideman D.A. ERC Guidelines 2015 Writing Group. European Resuscitation Council Guidelines for Resuscitation 2015: Section 1. Executive summary. Resuscitation. 2015; 95: 1-80. DOI: 10.1016/j.resuscitation.2015.07.038</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Кузовлев А.Н., Абдусаламов С.Н., Линчак Р.М. Реанимационные мероприятия в стационаре — проблема качества. Медицинский алфавит. 2017; 2, 17 (314): 35–39.</mixed-citation><mixed-citation xml:lang="en">Kuzovlev A.N., Abdusalamov S.N., Linchak R.M. Resuscitation measures in a hospital — a quality problem. Meditsinskiy alfavit. 2017; 2, 17 (314): 35–39 [In Russ.].</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Castillo J., Gallart A., Rodríguez E., Castillo J., Gomar C. Basic life support and external deﬁbrillation competences after instruction and at 6 months comparing face-to-face and blended training. Randomised trial. Nurse Educ Today. 2018; 65: 232–238. DOI: 10.1016/j.nedt.2018.03.008</mixed-citation><mixed-citation xml:lang="en">Castillo J., Gallart A., Rodríguez E., Castillo J., Gomar C. Basic life support and external deﬁbrillation competences after instruction and at 6 months comparing face-to-face and blended training. Randomised trial. Nurse Educ Today. 2018; 65: 232–238. DOI: 10.1016/j.nedt.2018.03.008</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Lin Y., Cheng A., Grant V.J., Currie G.R., Hecker K.G. Improving CPR quality with distributed practice and real-time feedback in pediatric healthcare providers — A randomized controlled trial. Resuscitation. 2018; 130: 6–12. DOI: 10.1016/j.resuscitation.2018.06.025</mixed-citation><mixed-citation xml:lang="en">Lin Y., Cheng A., Grant V.J., Currie G.R., Hecker K.G. Improving CPR quality with distributed practice and real-time feedback in pediatric healthcare providers — A randomized controlled trial. Resuscitation. 2018; 130: 6–12. DOI: 10.1016/j.resuscitation.2018.06.025</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Liu Y., Huang Z., Li H., Zheng G., Ling Q., Tang W., Yang Z. CPR feedback/prompt device improves the quality of hands-only CPR performed in manikin by laypersons following the 2015 AHA guidelines. Am J Emerg Med. 2018; 36 (11): 1980–1985. DOI: 10.1016/j.ajem.2018.02.034</mixed-citation><mixed-citation xml:lang="en">Liu Y., Huang Z., Li H., Zheng G., Ling Q., Tang W., Yang Z. CPR feedback/prompt device improves the quality of hands-only CPR performed in manikin by laypersons following the 2015 AHA guidelines. Am J Emerg Med. 2018; 36 (11): 1980–1985. DOI: 10.1016/j.ajem.2018.02.034</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Wagner M., Bibl K., Hrdliczka E., Steinbauer P., Stiller M., Gröpel P., Goeral K., Salzer-Muhar U., Berger A., Schmölzer G.M., Olischar M. Effects of Feedback on Chest Compression Quality: A Randomized Simulation Study. Pediatrics. 2019; 143 (2): e20182441. DOI: 10.1542/peds.2018-2441</mixed-citation><mixed-citation xml:lang="en">Wagner M., Bibl K., Hrdliczka E., Steinbauer P., Stiller M., Gröpel P., Goeral K., Salzer-Muhar U., Berger A., Schmölzer G.M., Olischar M. Effects of Feedback on Chest Compression Quality: A Randomized Simulation Study. Pediatrics. 2019; 143 (2): e20182441. DOI: 10.1542/peds.2018-2441</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Pritchard J., Roberge J., Bacani J., Welsford M., Mondoux S. Implementation of Chest Compression Feedback Technology to Improve the Quality of Cardiopulmonary Resuscitation in the Emergency Department: A Quality Initiative Test-of-change Study. Cureus. 2019 29; 11 (8): e5523. DOI: 10.7759/cureus.5523</mixed-citation><mixed-citation xml:lang="en">Pritchard J., Roberge J., Bacani J., Welsford M., Mondoux S. Implementation of Chest Compression Feedback Technology to Improve the Quality of Cardiopulmonary Resuscitation in the Emergency Department: A Quality Initiative Test-of-change Study. Cureus. 2019 29; 11 (8): e5523. DOI: 10.7759/cureus.5523</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
