Preview

General Reanimatology

Advanced search

Efficacy and Safety of Electrical Ventricular Defibrillation: The Experiment and Clinic

https://doi.org/10.15360/1813-9779-2012-4-79

Abstract

The paper provides the results of the 1990—2010 experimental and clinical studies on the optimization of the efficiency of electrical ventricular defibrillation using the Russian bipolar quasi-sinusoidal impulse. The comprehensive study of the influence of major cardiac and extracardiac factors, such as heart failure, the type and duration of fibrillation, its amplitude and frequency characteristics, chest resistance, electrode sizes, administration of antiarrhythmic drugs, and phase 2 impulse amplitude on the efficiency and safety of defibrillation, could formulate a number of new propositions and solve some methodological and methodic issues. The dose-dependent effectiveness of the quasi-sinusoidal impulse has been first investigated in patients with induced, spontaneous primary and secondary fibrillation and ventricular tachycardia. Low-energy (Key words: defibrillation, bipolar quasi-sinusoidal impulse.

About the Author

V. A. Vostrikov



References

1. Гурвич Н. Л.

2. Гурвич Н. Л., Макарычев В. А.Дефибрилляция сердца двухфазными электрическими импульсами.Кардиология.1967; 5 (7): 109—11

3. Гурвич Н. Л., Табак В. Я., Богушевич М. С., Венин И. В.Дефибрилляция сердца двухфазным импульсом в эксперименте и клинике.Кардиология.1971; 9 (8): 126—130.

4. Венин И. В., Гурвич Н. Л., Олифер Б. М., Пасичник Т. В., Савельев В. И., Сорокин В. Н., Цукерман Б. М., Шерман А. М.Дефибриллятор. Авторское свидетельство СССР № 258526 с приоритетом от 5. 05. 1968 г.Бюл. изобретений и товарных знаков.1970; 1.

5. Arredondo M. T., Guillen S. G., Quinteiro R. A.Effect of amiodarone on ventricular fibrillation and defibrillation thresholds in the heart under normal and ischemic conditions.Eur. J. Pharmacol.1986; 125 (1): 23—28.

6. Echt D. S., Black J. N., BarbeyJ. T., Coxe D. R., Cato E.Evaluation antiarrhythmic drugs on defibrillation energy requirements in dogs.Circulation.1989; 79 (5): 1106—1117.

7. Востриков В. А., Богушевич М. С., Холин П. В.Трансторакальная дефибрилляция желудочков сердца: эффективность и безопасность моно- и биполярного импульсов.Анестезиология и реаниматология.1994; 5: 9—11.

8. Востриков В. А., Богушевич М. С.Влияние амплитуды 2—й фазы биполярного синусоидального импульса на эффективность наружной дефибрилляции желудочков сердца.Бюл. эксперим. биологии и медицины.2000; Приложение 2: 40—41.

9. Востриков В. А., Богушевич М. С., Михайлов И. В.Влияние пироме-каина и новокаинамида на эффективность наружной дефибрилляции желудочков сердца.Кардиология.1999; 37 (12): 40—45.

10. Востриков В. А., Богушевич М. С.Влияние амиодарона на эффективность дефибрилляции желудочков сердца импульсами тока монополярной и биполярной синусоидальной форм.Анестезиология и реаниматология.2000; 6: 51—54.

11. Востриков В. А.Функциональное повреждение сердца монополярным и биполярным импульсами тока дефибриллятора.Бюл. экспе-рим. биологии и медицины.1993; 116 (12): 654—655.

12. Гурьянов М. И.Частотная характеристика неусвоения ритма при фибрилляции желудочков сердца собаки.Общая реаниматология.2010; 6 (4): 58—65.

13. Востриков В. А., Сыркин А. Л., Холин П. В., Разумов К. В.Внутри-больничная дефибрилляция желудочков сердца: эффективность биполярного квазисинусоидального импульса.Кардиология.2003; 43 (12): 51—58.

14. Walcott G. P., Walker R. G., Cates A. W., Krassowska W., Smith W. M., Ideker R. E.Choosing the optimal monophasic and biphasic waveforms for ventricular defibrillation.J. Cardovasc. Electrophysiol.1995; 6 (9): 737—750.

15. Li Y., Ristagno G., Yu T., Bisera J., Weil M. H., Tang W.A comparison of defibrillation efficacy between different impedance compensation techniques in high impedance porcine model.Resuscitation.2009; 80 (11): 1312—1317.

16. Востриков В. А., Горбунов Б. Б., Гусев А. Н., Гусев Д. В., Иткин Г. П., Конышева Е. Г., Мамекин К. А., Нестеренко И. В., Селищев С. В., Те-лышев Д. В.Сравнение на высокоомных моделях экспериментальных животных эффективности биполярных импульсов дефибрилляции: трапецеидальных, прямолинейного и квазисинусоидального импульса Гурвича-Венина.Медицинская техника.2010; 6: 1—6.

17. Востриков В. А., Горбунов Б. Б., Гусев А. Н., Гусев Д. В., Иткин Г. П., Конышева Е. Г., Нестеренко И. В., Селищев С. В.Дефибрилляция желудочков сердца: сравнительная эффективность биполярных квазисинусоидального и прямолинейного импульсов дефибрилляции на модели животных с высоким сопротивлением грудной клетки.Кардиология и сердечно-сосудистая хирургия.2011; 4 (3): 61—64.

18. Франек Ондржей.Использование автоматического наружного дефибриллятора (случай из практики).Общая реаниматология.2011; 7 (1): 65—67.

19. Востриков В. А.Электрическая дефибрилляция при внезапной остановке сердца на догоспитальном этапе.Общаяреаниматология.2005; 1 (3): 41—45.

20. Koster R. W., Baubin M. A., Bossaert L. L., Caballero A., Cassan P., Castren M., Granja C., Handley A. J., Monsieurs K. G., Perkins G. D., Raff ay V., Sandroni C.European Resuscitation Council Guidelines for Resuscitation 2010. Section 2. Adult Basic Life Support and Use of Automated External Defibrillators.Resuscitation.2010; 81 (10): 1277—1292.

21. Vostrikov V. A., Gorbunov B. B.Optimization of bipolar pulses of external defibrillators based on the repolarization hypothesis.Biomed. Eng.2009; 43 (2): 62—67.


Review

For citations:


Vostrikov V.A. Efficacy and Safety of Electrical Ventricular Defibrillation: The Experiment and Clinic . General Reanimatology. 2012;8(4):79. (In Russ.) https://doi.org/10.15360/1813-9779-2012-4-79

Views: 1327


Creative Commons License