Occult Erythrocytic Membrane Damages Upon Physical and Pharmacological Exposures
https://doi.org/10.15360/1813-9779-2006-6-55-60
Abstract
The study was undertaken to develop a method for detection of occult damages to erythrocytic membranes exposed to a pulsed electric field, ionizing radiation of various nature, the blood substitute perfluorane, and some chemicals. The experimental results led to the conclusion that calibration electroporation was effective in identifying occult erythrocytic membrane damages when perfluorane was administered at different concentrations and when y-radiation was used in small doses (0.5—10 cGy). Non-additivity of the rate constants of a reduction in the suspension count of red blood cells was observed when perfluorane was added or when y-radiation and a pulsed electric field had impact on biological membranes.
About the Authors
V. V. MorozA. M. Chernysh
M. S. Bogushevich
Ye. K, Kozlova
U. A. Bliznyuk
P. Yu. Alekseyeva
A. P. Kozlov
References
1. Козлова Е. К., Черняев А. П., Шведунов В. И. и др. Особенности комбинированного действия пучка ускоренных электронов и импульсного электрического поля на биологические клетки. Биомедицинские технологии и радиоэлектроника 2004; 5—6: 65—74.
2. Козлова Е. К., Черняев А. П., Черныш А. М., Алексеева П. Ю. Исследование воздействия гамма-излучения на эритроциты с помощью электропорации. Вестн. Моск. у-та. Сер. 3. Физика. Астрономия 2005; 3: 19—22.
3. Шмидт Р., Тевс Г. (ред.) Физиология человека. 2. М.: Мир; 1996.
4. Canatella P. J., Karr J. F., Petros J. A., Prausnits M. R. Quantitative study of elеctroporation-mediated molecular uptake and cell viability. Biophys. J. 2001; 80: 755—764.
5. Tekle E., Astumian R. D., Chock P. B. Selective and asymmetric molecular transport across electroporated cell membranes. Proc. Natl. Acad. Sci. USA 1994; 91: 11512—11516.
6. Rodnenkov O. V., Luneva O. G., Ulyanova N. A. et al. Erythrocyte membrane fluidity and haemoglobin haemoporphyrin conformation: features revealed in patients with heart failure. Pathophysiology 2005; 11: 209—213.
7. Мороз В. В., Козлова Е. К., Богушевич М. С. и др. Перфторан в суспензии крови. Эффекты закрепляющего и разрушающего действия на модифицированные электрическими импульсами мембраны. Общая реаниматология 2005; 1 (3): 5—10.
8. Козлова Е. К., Мороз В. В., Богушевич М. С. и др. Влияние формы электрического импульса на электропорацию мембран эритроцитов. Общая реаниматология 2005; 1(1): 42—46.
9. Козлова Е. К., Черныш А. М., Мороз В. В. и др. Комбинированное действие гамма-излучения, импульсного электрического поля и перфторана на мембраны эритроцитов. Мед. физика 2004; 4: 49—54.
10. Heath R. L. Scintillation spectrometry. Gamma-ray spectrum catalogue, Ray spectrometry center. Idaho: National Engineering & Environmental Laboratory; 1997.
11. Черныш А. М., Козлова Е. К., Мороз В. В. и др. Способ выявления повреждения мембран эритроцитов. Патент № 2269127. 2004.
Review
For citations:
Moroz V.V., Chernysh A.M., Bogushevich M.S., Kozlova Ye.K., Bliznyuk U.A., Alekseyeva P.Yu., Kozlov A.P. Occult Erythrocytic Membrane Damages Upon Physical and Pharmacological Exposures. General Reanimatology. 2006;2(6):55-60. (In Russ.) https://doi.org/10.15360/1813-9779-2006-6-55-60